Company Description: PowerMore designs, builds, and maintains commercial and industrial rooftop solar plants across India, under EPC, PPA, and RESCO models. We care about plants that generate what they promise for 25 years, which means getting the electrical design right on paper and making sure the site matches it.
We are looking for a hands-on electrical engineer who has either worked on building MEP electrical, on the DC side of solar plants, or ideally both. You will design rooftop systems in AutoCAD, PVsyst, and Arka360, validate that the BOQ and ratings are correct, go to site to audit what was built, find the faults in running plants, and fix them. You should be as comfortable with a clamp meter and an IR tester as you are with a single-line diagram on your screen.
Role Description
1. Design and Engineering
· Prepare rooftop solar layouts, string diagrams, DC and AC single-line diagrams (SLDs), cable routing and earthing layouts in AutoCAD.
· Run energy yield simulations in PVsyst and layout/shading studies in Arka360 (or similar tools such as HelioScope / SketchUp); explain losses and PR to the sales and customer teams.
· Do string sizing against the inverter MPPT window using module Voc, Isc, Vmp, Imp and temperature coefficients at site minimum and maximum temperatures.
· Size DC and AC cables for ampacity and voltage drop; select and rate fuses, DC isolators, SPDs (Type 1/2), MCBs, MCCBs, ACDB/DCDB and protection relays.
· Design earthing and lightning protection systems and calculate earth pit requirements.
· Validate designs received from vendors or consultants, and review BOQs so the right material reaches site.
· Check rooftop suitability for walkways, setbacks, cable trays, access and load points. 2. Site execution, Testing and Commissioning
· Conduct site surveys (recce) for new projects: roof condition, shading, existing LT panel, transformer and point of interconnection.
· Supervise installation quality on site: module mounting, MC4 crimping, string wiring, cable dressing, earthing, inverter and ACDB installation.
· Carry out pre-commissioning and commissioning tests: polarity, string Voc and Isc, insulation resistance (IR), earth resistance, continuity, and inverter start-up checks, in line with IEC 62446.
· Prepare test reports, as-built drawings, and handover documentation.
· Coordinate with DISCOM and electrical inspectorate for net metering, CEIG / CEA approvals and inspections where required. 3. Troubleshooting and Plant Performance
· Diagnose problems in running rooftop plants: underperforming strings, hotspots, ground faults, low IR alarms, inverter trips, PID, mismatch, shading and soiling losses, and connector or cable failures.
· Use thermal imaging, IV curve tracing, and string current comparison to locate faults.
· Compare actual generation with PVsyst estimates, find the gap, and recommend corrective actions.
· Write clear root cause reports and close issues with the O&M team. 4. Safety and Compliance
· Follow and enforce electrical safety practices.
· Ensure designs comply with relevant standards: IEC 62548, IEC 60364-7-712, IEC 62446, IS 3043 (earthing), IS 732, National Building Code, CEA safety regulations, MNRE / ALMM requirements and local DISCOM norms. Must-have Experience
· B.
E. / B.
Tech in Electrical or Electrical & Electronics Engineering (Diploma with strong relevant experience will also be considered).
· 6 – 8 years of experience in at least one of these, preferably both: o Building MEP (Electrical): LT distribution, panel schedules, load calculations, cable sizing, earthing, and lighting protection for commercial or industrial buildings. o Solar plants (DC side): string design, DC cabling, protection, testing and commissioning of rooftop or ground-mounted plants.
· Has worked on rooftop solar projects and personally identified and fixed issues in a running plant.
· Strong working knowledge of AutoCAD; working knowledge of PVsyst; experience with Arka360 or a similar solar design tool.
· Understands equipment ratings and datasheets: modules, inverters, cables, fuses, SPDs, isolators, breakers and transformers, and can tell when something is under-rated.
· Can use and interpret readings from field instruments (see below).
· Willing to travel to sites and spend time on rooftops. Instruments you should be comfortable with
· Digital multimeter and DC clamp meter
· Insulation resistance tester (megger)
· Earth resistance tester
· Solar PV tester / IV curve tracer
· Thermal imaging camera
· Irradiance meter (pyranometer or handheld solar meter)
· Power quality analyser (good to have) Good to have
· Experience with C&I rooftop projects above 100 kWp.
· Exposure to inverter monitoring portals and SCADA / remote monitoring.
· Knowledge of net metering, gross metering and open access processes in Indian states.
· Familiarity with battery storage (BESS) and hybrid inverters.
· Basic understanding of structural design for module mounting.
· Valid electrical supervisor licence. What success looks like in the first 6 months
· Designs you prepare go to site without major rework.
· Every project you commission has a complete test report and as-built set.
· You have audited our existing plants and closed the top generation issues you found.
· Sales and site teams come to you for technical answers.
· Prepare rooftop solar layouts, string diagrams, DC and AC single-line diagrams (SLDs), cable routing and earthing layouts in AutoCAD.
· Run energy yield simulations in PVsyst and layout/shading studies in Arka360 (or similar tools such as HelioScope / SketchUp); explain losses and PR to the sales and customer teams.
· Do string sizing against the inverter MPPT window using module Voc, Isc, Vmp, Imp and temperature coefficients at site minimum and maximum temperatures.
· Size DC and AC cables for ampacity and voltage drop; select and rate fuses, DC isolators, SPDs (Type 1/2), MCBs, MCCBs, ACDB/DCDB and protection relays.
· Design earthing and lightning protection systems and calculate earth pit requirements.
· Validate designs received from vendors or consultants, and review BOQs so the right material reaches site.
· Check rooftop suitability for walkways, setbacks, cable trays, access and load points. 2. Site execution, Testing and Commissioning
· Conduct site surveys (recce) for new projects: roof condition, shading, existing LT panel, transformer and point of interconnection.
· Supervise installation quality on site: module mounting, MC4 crimping, string wiring, cable dressing, earthing, inverter and ACDB installation.
· Carry out pre-commissioning and commissioning tests: polarity, string Voc and Isc, insulation resistance (IR), earth resistance, continuity, and inverter start-up checks, in line with IEC 62446.
· Prepare test reports, as-built drawings, and handover documentation.
· Coordinate with DISCOM and electrical inspectorate for net metering, CEIG / CEA approvals and inspections where required. 3. Troubleshooting and Plant Performance
· Diagnose problems in running rooftop plants: underperforming strings, hotspots, ground faults, low IR alarms, inverter trips, PID, mismatch, shading and soiling losses, and connector or cable failures.
· Use thermal imaging, IV curve tracing, and string current comparison to locate faults.
· Compare actual generation with PVsyst estimates, find the gap, and recommend corrective actions.
· Write clear root cause reports and close issues with the O&M team. 4. Safety and Compliance
· Follow and enforce electrical safety practices.
· Ensure designs comply with relevant standards: IEC 62548, IEC 60364-7-712, IEC 62446, IS 3043 (earthing), IS 732, National Building Code, CEA safety regulations, MNRE / ALMM requirements and local DISCOM norms. Must-have Experience
· B.
E. / B.
Tech in Electrical or Electrical & Electronics Engineering (Diploma with strong relevant experience will also be considered).
· 6 – 8 years of experience in at least one of these, preferably both: o Building MEP (Electrical): LT distribution, panel schedules, load calculations, cable sizing, earthing, and lighting protection for commercial or industrial buildings. o Solar plants (DC side): string design, DC cabling, protection, testing and commissioning of rooftop or ground-mounted plants.
· Has worked on rooftop solar projects and personally identified and fixed issues in a running plant.
· Strong working knowledge of AutoCAD; working knowledge of PVsyst; experience with Arka360 or a similar solar design tool.
· Understands equipment ratings and datasheets: modules, inverters, cables, fuses, SPDs, isolators, breakers and transformers, and can tell when something is under-rated.
· Can use and interpret readings from field instruments (see below).
· Willing to travel to sites and spend time on rooftops. Instruments you should be comfortable with
· Digital multimeter and DC clamp meter
· Insulation resistance tester (megger)
· Earth resistance tester
· Solar PV tester / IV curve tracer
· Thermal imaging camera
· Irradiance meter (pyranometer or handheld solar meter)
· Power quality analyser (good to have) Good to have
· Experience with C&I rooftop projects above 100 kWp.
· Exposure to inverter monitoring portals and SCADA / remote monitoring.
· Knowledge of net metering, gross metering and open access processes in Indian states.
· Familiarity with battery storage (BESS) and hybrid inverters.
· Basic understanding of structural design for module mounting.
· Valid electrical supervisor licence. What success looks like in the first 6 months
· Designs you prepare go to site without major rework.
· Every project you commission has a complete test report and as-built set.
· You have audited our existing plants and closed the top generation issues you found.
· Sales and site teams come to you for technical answers.